Safe
- IP66 protection level
- AC&DC SPD type II, always guarding the inverter
- AFCI optional
- Smart IV Curve scan for early panel diagnosis
Robust
- Robust back-up ability, switch over time <10ms, up to 150% EPS output for 10s
- Support off-grid operation
Economic
- Maximum 200% PV input
- Maximum 40A input current per MPpT, support high power solar panel
Intelligent
- AI ready, forecasting solar generation and load consumption, smart energy management strategy*
- VPP ready, SolaX cloud supports resource aggregator (2030.5, OpenADR )
- Support smart scene function, intelligent loads management(e.g., Heat pump, EV charger)*
- Micro-grid ready, supporting a variety of scenarios, both on-grid and off-grid, balancing power between PCS and Hybrid in real time
- Support 7x24h scheduling mode
- Support Wireless meter solution
- Dual independent battery ports are ready to expand more capacity
It offers 24/7 smart energy management, utilizing AI to forecast solar generation and load consumption, with VPP readiness and intelligent scene functions for optimal energy use. It delivers high efficiency and reliability with a switch-over time of less than 10ms and up to 150% EPS output for 10 seconds, supporting off-grid operations. Additionally, it is highly cost-effective, supporting up to 200% PV input and 40A input current per MPPT, making it ideal for high-power solar panels and ensuring maximum energy savings and efficiency.
| Category | X3-AELIO-49.9K | |
| DC Side | Max. PV input power [kW] | 100 |
| Max. PV input voltage [V] | 1000 | |
| Start-up voltage [V] | 200 | |
| Nominal input voltage [V] | 650 | |
| MPPT voltage range [V] | 160-950 | |
| No. of MPP trackers / Strings per MPP tracker | 5 (2 per MPPT) | |
| Max. input current per MPPT [A] | 40 | |
| Max. input short circuit current per MPPT [A] | 50 | |
| AC Side | Rated AC output power [kW] | 49.9 |
| Rated AC output current [A] | 72.3 | |
| Max. AC output apparent power [kVA] | 49.9 | |
| Max. AC output current [A] | 83.2 | |
| Nominal AC voltage [V] | 3P4W, 400/230, 380/220 | |
| Rated AC grid frequency [Hz] | 50 / 60 | |
| Adjustable Power Factor range | 1 (0.8 Leading ~ 0.8 Lagging) | |
| THDi (Rated power) [%] | < 3 | |
| Battery Side | Battery type | Lithium – ion |
| Battery voltage range [V] | 180 – 820 | |
| Max. charge / discharge current [A] | 160 (80×2) | |
| EPS Output (with battery) | Peak apparent AC power [kVA] | 49.9 |
| Nominal voltage [V]; Frequency [Hz] | 3P4W, 400/230V, 380/220V; 50/60HZ | |
| Max. output continuous current [A] | 72 | |
| Switch time [ms] | < 10 | |
| General | Max. efficiency [%] | 98 |
| European weighted efficiency [%] | 97.2 | |
| Ingress protection | IP66 | |
| Operating ambient temperature range [°C] | – 35 ~ 60 | |
| Max. operating altitude [m] | < 3000 | |
| Relative humidity [%] | 0 ~ 100 | |
| Typical noise emission [dB] | < 70 | |
| Dimensions (W×H×D) [mm] | 820 × 670 × 257 | |
| Net weight [kg] | < 100 | |
| Cooling concept | Smart air cooling | |
| Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |
| Display | LCD (optional) | |
| Power Consumption | Standby consumption (night) [W] | < 10 |
| Protection | Over/under voltage protection | Yes |
| DC isolation protection | Yes | |
| DC reverse-polarity protection | Yes | |
| Grid monitoring | Yes | |
| DC injection monitoring | Yes | |
| Back feed current monitoring | Yes | |
| Residual current detection | Yes | |
| Anti-islanding protection | Yes | |
| Over temperature protection | Yes | |
| SPD (DC/AC) | Type II/Type II | |
| Arc-fault circuit interrupter (AFCI) | Optional | |
| Standard | Safety | EN/IEC 62109-1/-2 |
| EMC | EN 61000-6-1/2/3/ 4, EN 61000-3-11/12, EN 55011, IEC 62920 | |
| Cetification | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR |









